AZ300-I2-ST-SD2P Machine safety switch with separate actuator

AZ300-I2-ST-SD2P
Repeated individual coding with RFID technology
Coding level "High" according to ISO 14119
Connector M12, 8-pole
serial diagnostic output
Individual coding
Suitable for mounting to profile systems
Thermoplastic enclosure
RFID-technology for needs-based protection against tampering
3 different directions of actuation
Compact design
3 LEDs to show operating conditions
Suitable for hinged and sliding guards
Series-wiring
  • SKU
    4030661435855
  • Manufacturer code
    103001467
  • Type of Execution, IP Protection class, General
    IP67
    IP66
    IP69K
  • Type of Execution, Mechanical life, minimum,
    1000000 Operations
  • Height, Sensor
    100 mm
  • Length, Sensor
    35 mm
  • Width, Sensor
    85 mm
  • Electrical data, Utilisation category
    DC-13
    DC-12
  • Housing material
    Glass-fibre, reinforced thermoplastic
  • Standard, standards
    EN IEC 60947-5-1
    EN ISO 13849-1
    EN IEC 61508
    EN IEC 60947-5-3
  • Number, Safety contacts
    2
  • PIM maintenance status
    Discharge "Online catalog"
  • PNV, standard, certificates
    cULus
    TÜV
    ECOLAB
    FCC
    IC
  • Electrical data, Terminal, Connector, Transmitter, General
    Connector M12, 8-pole, A-coded
  • Safety parameters, Mission time
    20 Year(s)
  • Safety parameter
    EN IEC 61508
  • SAP, basic quantity unit
    Piece
  • SAP, EAN (European Article Number)
    4030661435855
  • SAP, product group
    Initial
  • Included in delivery, number and type, general
    Actuator must be ordered separately.
  • Temperature, Ambient temperature[generated product variant]
    +0 ... +60 °C
  • Temperature, ambient temperature, maximum
    60 °C
  • Temperature, ambient temperature, minimum
    0 °C
  • Voltage, Rated impulse withstand voltage
    0.8 kV
  • Voltage, rated insulation voltage
    32 VDC
  • Web Type
    Product range
  • Coding, Coding level according to EN ISO 14119
    High
  • Current, Required rated short-circuit current to EN 60947-5-1
    100 A
  • Type of Execution, Overvoltage category IEC/EN 60664-1
    II
  • Note, General
    For doors that are flush with the door frame, the optional m
    For glass and Makrolon doors, the optional mounting kit MS-A
  • Safety parameters, Category, EN ISO 13849
    4
  • Safety parameters, Performance Level,
    e
  • Temperature, storage and transport temperature,[generated product variant]
    -10 ... +90 °C
  • Temperature, storage and transport temperature, maximum
    90 °C
  • Temperature, storage and transport temperature, minimum
    -10 °C
  • Type of Execution, for degree of pollution VDE 0100
    3
  • Type of Execution, Overvoltage category VDE 0100
    3
  • Type of Execution, Protection class (Operating resource)
    2
  • Note, LED switching conditions display
    Supply voltage UB: LED green
    Operating condition: LED green
    Error / functional defect: LED red
  • Safety values, PFD value
    0.00000000052 /h
  • Safety parameters, Safety Integrity Level (SIL)
    3
  • Time, Reaction, maximum
    100 ms
  • Selection (Yes/No), Integral System Diagnostics, status
    Yes
  • Included in delivery, number and type, mounting material
    2 x M6
  • Recommendation, actuator
    AZ/AZM300-B1
  • Coding, general information
    Individual coding, multiple teaching
  • Current, consumption at 24V
    5 mA
  • Current, consumption at 24V, safety inputs
    5 mA
  • Current, Residual current, Fail-safe output, maximum
    0.5 mA
  • Current, operation current, serial diagnostic SD
    150 mA
  • Current, Rated operating current
    50 mA
  • Current, Rated operating current, Safe digital outputs
    250 mA
  • Current, Utilisation category DC-13, Diagnostic output
    0.05 A
  • Current, Utilisation category DC-13, Fail-safe digital output
    0.25 A
  • Type of execution, switching output, diagnostic output, electric
    short-circuit proof, p-type
  • Type of execution, switching output, fail-safe output, electric
    short-circuit proof, p-type
  • Type of execution, switching output, seriel diagnostic SD, electric
    short-circuit proof, p-type
  • Area, ensured switch distance OFF Sar
    20 mm
  • Area, ensured switch distance ON Sao
    1 mm
  • Range, switch distance S, typical
    2 mm
  • Electrical data, Connector 1, Pin assignment, PIN 1
    A1 Supply voltage UB
  • Electrical data, Connector 1, Pin assignment, PIN 2
    X1 Safety input 1
  • Electrical data, Connector 1, Pin assignment, PIN 3
    A2 GND
  • Electrical data, Connector 1, Pin assignment, PIN 4
    Y1 Safety output 1
  • Electrical data, Connector 1, Pin assignment, PIN 5
    OUT serial diagnostic output
  • Electrical data, Connector 1, Pin assignment, PIN 6
    X2 Safety input 2
  • Electrical data, Connector 1, Pin assignment, PIN 7
    Y2 Safety output 2
  • Electrical data, Connector 1, Pin assignment, PIN 8
    without function
  • Electrical data, Designation device connection, SD interface
    OUT
  • Electrical data, Fuse rating, Current, maximum
    2 A
  • Electrical data, Inputs, Switching thresholds
    −3 V … 5 V (Low)
    15 V … 30 V (High)
  • Electrical data, inputs, switching thresholds for fail-safe inputs
    −3 V … 5 V (Low)
    15 V … 30 V (High)
  • Electrical data, wiring capacity, serial diagnostic SD, maximum
    50 nF
  • Force, Latching force, adjustable, position 1
    25 N
  • Force, Latching force, adjustable, position 2
    50 N
  • Note, Mechanical lifetime
    > 50,000 operations for door weights ≤ 5 kg
    Actuating speed ≤ 0.5 m/s
  • Notes, length, sensor chain
    Cable length and cross-section change the voltage drop depen
  • Note, series connection, sensors
    Unlimited number of devices, oberserve external line fusing,
  • Review, Resistance to vibrations to EN 60068-2-6
    10 … 150 Hz, amplitude 0.35 mm
  • Review, restistance to shock
    30 g / 11 ms
  • Time, Duration of risk, maximum
    200 ms
  • Time, switching frequency, approx.
    0.5 Hz
  • Time, Time to readiness, maximum
    5000 ms
  • Voltage, voltage drop Ud, maximum
    4 V
  • Voltage, Utilisation category DC-13, Diagnostic output
    24 VDC
  • Voltage, Utilisation category DC-13, Fail-safe digital output
    24 VDC
  • Selection (Yes/No), Actuator monitored
    Yes
  • Selection (Yes/No), Short-circuit recognition
    Yes
  • Selection (Yes/No), latching
    Yes
  • Selection (Yes/No), EPLAN
    Yes
  • Selection (Yes/No), Safety functions
    Yes
  • Selection (Yes/No), Serial diagnostics
    Yes
  • Selection (Yes/No), Series-wiring
    Yes
  • Selection (Yes/No), Short circuit detection
    Yes
  • This product is unavailable