Already a member? Sign in or create an account

Cart

Product Quantity  

Your cart is empty.

RSS260-I2-D-LSTM12-5-0,25M Electronic machine safety sensor

RSS260-I2-D-LSTM12-5-0,25M
5-pole cable connector M12 for individual connection
Repeated individual coding with RFID technology
Coding level "High" according to ISO 14119
Simple mounting without additional angle
Frontal and lateral actuation enabled
RFID-technology for needs-based protection against tampering
Thermoplastic enclosure
  • SKU
    4030661512259
  • Manufacturer code
    103025103
  • Current, Residual current, Fail-safe output, maximum
    0.5 mA
  • Current, Rated operating current
    600 mA
  • Current, Rated operating current, Safe digital outputs
    250 mA
  • Current, output current, fail-safe output, maximum
    0.25 A
  • Current, Utilisation category DC-12, Fail-safe digital output
    0.25 A
  • Current, Utilisation category DC-13, Fail-safe digital output
    0.25 A
  • Type of Execution, for degree of pollution VDE 0100
    3
  • Type of Execution, Housing construction form
    Block
  • Type of Execution, Terminals, mechanical
    not flush
  • Type of Execution, IP Protection class, General
    IP67
    IP65
  • Type of Execution, Overvoltage category VDE 0100
    3
  • Type of Execution, Overvoltage category IEC/EN 60664-1
    III
  • Type of execution, sensor, topology
    Sensor for series wiring
  • Type of execution, switching output, fail-safe output, electric
    short-circuit proof, p-type
  • Distance, Hysteresis, Mechanical, maximum
    2 mm
  • Distance, Repeat accuracy R R
    0.5 mm
  • Length, Sensor
    29.5 mm
  • Electrical data, Connector 1, Pin assignment, PIN 1
    A1 Supply voltage UB
  • Electrical data, Connector 1, Pin assignment, PIN 2
    Y2 Safety output 2
  • Electrical data, Connector 1, Pin assignment, PIN 3
    A2 GND
  • Electrical data, Connector 1, Pin assignment, PIN 4
    Y1 Safety output 1
  • Elektrische Daten, Absicherung des Diagnoseausganges, Allgemein
    short-circuit proof, p-type
  • Elektrische Daten, Absicherung des Sicherheitsausganges, Allgemein
    short-circuit proof, p-type
  • Material, active area
    Glass-fibre, thermoplastic
  • Housing material
    Plastic, thermoplastic, self-extinguishing
  • Standard, standards
    EN IEC 61508
    EN IEC 60947-5-3
    EN ISO 13849-1
  • Note, LED switching conditions display
    LED red: Fault
    LED yellow: Operating condition
    (1) LED green: Supply voltage
  • Number, fail-safe digital outputs
    2
  • PIM maintenance status
    Discharge "Online catalog"
  • PNV, standard, certificates
    cULus
    TÜV
    UKCA
    FCC
    IC
    ANATEL
  • Recommendation, actuator
    RST16-1
    RST-U-2
    RST260-1
  • Recommended, Safety switchgear
    SRB-E-301ST
    SRB-E-201LC
  • Type of electric connection
    Connector M12, 5-pole, A-coded
  • Review, Resistance to vibrations to EN 60068-2-6
    10 … 55 Hz, amplitude 1 mm
  • Review, restistance to shock
    30 g / 11 ms
  • Safety parameters, Category, EN ISO 13849
    4
  • Safety parameters, Mission time
    20 Year(s)
  • Safety parameter
    EN IEC 61508
    EN ISO 13849-1
  • Performance Level
    e
  • Safety values, PFD value
    0.00000000068 /h
  • Safety parameters, Safety Integrity Level (SIL)
    3
  • SAP, basic quantity unit
    Piece
  • SAP, EAN (European Article Number)
    4030661512259
  • SAP, product group
    Initial
  • SAP, gross weight
    121.000 g
  • SAP, net weight
    121.000 g
  • Included in delivery, number and type, general
    Actuator must be ordered separately.
  • Temperature, Ambient temperature[generated product variant]
    -28 ... +65 °C
  • Temperature, ambient temperature, maximum
    65 °C
  • Temperature, ambient temperature, minimum
    -28 °C
  • Temperature, storage and transport temperature,[generated product variant]
    -28 ... +85 °C
  • Temperature, storage and transport temperature, maximum
    85 °C
  • Temperature, storage and transport temperature, minimum
    -28 °C
  • Time, Duration of risk, maximum
    200 ms
  • Time, Reaction, maximum
    100 ms
  • Tolerance, operating voltage, DC, maximum
    10 %
  • Tolerance, operating voltage, DC, minimum
    -15 %
  • Voltage, voltage drop Ud, maximum
    1 V
  • Voltage, Rated impulse withstand voltage
    0.8 kV
  • Voltage, rated insulation voltage
    32 VDC
  • Voltage, rated operating voltage
    24 VDC -15% / +10%
  • Voltage, rated operating voltage
    24 VDC
  • Voltage, type
    DC
  • Voltage, Utilisation category DC-12, Fail-safe digital output
    24 VDC
  • Voltage, Utilisation category DC-13, Fail-safe digital output
    24 VDC
  • Web Type
    Product range
  • Selection (yes/no), cascadable
    Yes
  • Selection (Yes/No), Short-circuit recognition
    Yes
  • Selection (Yes/No), Safety functions
    Yes
  • Selection (Yes/No), Integral System Diagnostics, status
    Yes
  • Selection (Yes/No), Short circuit detection
    Yes
  • Selection (Yes/No), Traceparts
    Yes
  • Current, Utilisation category DC-12, Diagnostic output
    0.05 A
  • Current, Utilisation category DC-13, Diagnostic output
    0.05 A
  • Electrical data, Connector 1, Pin assignment, PIN 5
    OUT Diagnostic output
  • Electrical data, Utilisation category DC-12, Diagnostic output [generated product variant]
    24 VDC / 0.05 A
  • Number, Semi-conductor outputs with signaling function
    1
  • Voltage, Utilisation category DC-12, Diagnostic output
    24 VDC
  • Voltage, Utilisation category DC-13, Diagnostic output
    24 VDC
  • Coding, Coding level according to EN ISO 14119
    High
  • Type of application, Actuating panel
    lateral
    front side
  • Current, Required rated short-circuit current to EN 60947-5-1
    100 A
  • Type of Execution, Active area
    lateral
    front
  • Height, Sensor
    18 mm
  • Width, Sensor
    39.2 mm
  • Standard, EMC rating
    IEC 60947-3
  • Standard, interfering radiation
    IEC 61000-6-4
  • Note, Distance, Repeat accuracy R
    Axial offset: The long side allows for a maximum height misa
  • Notes, length, sensor chain
    Cable length and cross-section change the voltage drop depen
  • Number, LED's
    3
  • Selection (Yes/No), Diagnostic output
    Yes
  • Note, series connection, sensors
    Unlimited number of devices, oberserve external line fusing,
  • Voltage, rated operating voltage, maximum
    26.4 VDC
  • Voltage, rated operating voltage, minimum
    20.4 VDC
  • Type of application, Relative humidity, maximum
    93 %
  • Safety parameters, Coding levels according to EN ISO 14119  [generated product range]
    I1 variant: High
    I2 variant: High
    Standard coded v
  • Coding, general information
    Individual coding, multiple teaching
  • Current, consumption, Safety inputs
    5 mA
  • Current, Operating current, minimum
    0.5 mA
  • Current, operation current, serial diagnostic SD[generated product range]
    150 mA
  • Type of Execution, IP Protection class, General  [generated product range]
    IP65, IP67
  • Type of execution, mounting
    A 20 mm screw length usually suffices to mount the sensor. W
  • Type of execution, mounting, Screws
    2x M4
  • Height, permissible installation height above sea level, maximum
    2000 m
  • Electrical data, Classification, ZVEI CB24I: Sink, Safety digital inputs
    C1
  • Electrical data, Classification, ZVEI CB24I: Sink, fail-safe digital outputs
    C1
    C2
  • Electrical data, Classification, ZVEI CB24I: Source, Safety digital inputs
    C1
    C2
    C3
  • Electrical data, Classification, ZVEI CB24I: Source, fail-safe digital outputs
    C2
  • Electrical data, Designation device connection, Diagnostic outputs
    OUT
  • Electrical data, Designation device connection, Safety inputs
    X1 and X2
  • Electrical data, Designation device connection, Safety outputs
    Y1 and Y2
  • Electrical data, Fuse rating, General
    short-circuit proof, p-type
  • Electrical data, Fuse rating, Current, maximum
    2 A
  • Electrical data, wiring capacity, serial diagnostic SD, maximum[generated product range]
    50 nF
  • Standard, standards [generated product range]
    EN ISO 13849-1, EN IEC 60947-5-3, EN IEC 61508
  • Note, Relative humidity
    non-condensing
    non-icing
  • Note, operating voltage, DC
    stabilised PELV power supply
  • Power, transmit, RFID, maximum
    -6 dB/m
  • Safety values, PFD value
    0.00012
  • Time, frequency band, RFID
    125 kHz
  • Time, Reaction, Actuator, maximum
    100 ms
  • Time, Switching frequency, maximum
    1 Hz
  • Time, test pulse duration, maximum
    1 ms
  • Time, test pulse duration, safety, digital output, maximum
    1 ms
  • Time, test pulse interval, safety digital input, minimum
    100 ms
  • Time, test pulse interval, safety digital output, typical
    1000 ms
  • Time, Time to readiness, maximum
    2000 ms
  • Torque, tightening torque, screw, mounting, maximum
    0.8 Nm
  • Selection (Yes/No), Series-wiring
    Yes
  • Current, Rated operating current, diagnostic output
    50 mA
  • Area, ensured switch distance OFF Sar, Front
    18 mm
  • Ensured switching distance "OFFF", side
    15 mm
  • Area, ensured switch distance ON Sao, Front
    10 mm
  • Area, ensured switch distance ON Sao, lateral
    6 mm
  • Range, switch distance S, typical, front
    12 mm
  • Range, switch distance S, typical, side
    9 mm
  • Notice, Switch distance Sn
    Axial misalignment, a horizontal and vertical misalignment o
  • Note, ensured switch distance ON Sao
    The specifications of the safety switching distance Sao refer to a temperature range of
    -10 °C ... +60 °C. For a temperature range of -28 °C ... +65 °C, Sao is reduced by 2 mm.
  • Number, poles
    5
  • This product is unavailable

    This product is currently unavaliable, this could be due to a limited stock shortage, or because of discontinuation or replacement. For more information please contact us at b2b@tipteh.si.

  • Manufacturer Schmersal