Already a member? Sign in or create an account

Cart

Product Quantity  

Your cart is empty.

RSS16-I1-D-SK Electronic machine safety sensor

RSS16-I1-D-SK
Individual coding with RFID technology
Coding level "High" according to ISO 14119
Series-wiring unlimited
without latching
Thermoplastic enclosure
RFID-technology for needs-based protection against tampering
3 different directions of actuation
Door stop with magnetic latching
Connection terminal or plug connection
Suitable for series-wiring
Repeated individual coding with RFID technology
  • SKU
    4030661472256
  • Manufacturer code
    103010516
  • Current, Residual current, Fail-safe output, maximum
    0.5 mA
  • Current, Rated operating current
    2100 mA
  • Current, Rated operating current, Safe digital outputs
    1000 mA
  • Current, output current, fail-safe output, maximum
    1 A
  • Current, Utilisation category DC-12, Fail-safe digital output
    1 A
  • Current, Utilisation category DC-13, Fail-safe digital output
    1 A
  • Type of Execution, for degree of pollution VDE 0100
    3
  • Type of Execution, Housing construction form
    Block
  • Type of Execution, Terminals, mechanical
    not flush
  • Type of Execution, IP Protection class, General
    IP67
    IP65
  • Type of Execution, Overvoltage category VDE 0100
    3
  • Type of Execution, Overvoltage category IEC/EN 60664-1
    III
  • Type of execution, sensor, topology
    Sensor for series wiring
  • Type of execution, switching output, fail-safe output, electric
    p-type
  • Distance, Hysteresis, Mechanical, maximum
    2 mm
  • Distance, Repeat accuracy R R
    0.5 mm
  • Length, Sensor
    91 mm
  • Area, ensured switch distance OFF Sar
    30 mm
  • Area, ensured switch distance ON Sao
    12 mm
  • Range, switch distance S, typical
    15 mm
  • Elektrische Daten, Absicherung des Diagnoseausganges, Allgemein
    short-circuit proof, p-type
  • Elektrische Daten, Absicherung des Sicherheitsausganges, Allgemein
    short-circuit proof, p-type
  • Material, active area
    Glass-fibre, reinforced thermoplastic
  • Housing material
    Plastic, glass-fibre reinforced thermoplastic, self-extingui
  • Standard, standards
    EN IEC 60947-5-3
  • Note, LED switching conditions display
    LED green: Supply voltage
    LED red: Fault
    LED yellow: Operating condition
    Multi-coloured LED: Green, Red
  • Number, fail-safe digital outputs
    2
  • PIM maintenance status
    Discharge "Online catalog"
  • PNV, standard, certificates
    cULus
    TÜV
    UKCA
    FCC
    IC
    ANATEL
  • Recommendation, actuator
    RST16-1
  • Recommended, Safety switchgear
    PROTECT PSC1
    SRB-E-301ST
    SRB-E-201LC
  • Type of electric connection
    Screw terminals
  • Review, restistance to shock
    30 g / 11 ms
  • Safety parameters, Category, EN ISO 13849
    4
  • Safety parameters, Mission time
    20 Year(s)
  • Safety parameter
    EN IEC 61508
    EN ISO 13849-1
  • Performance Level
    e
  • Safety values, PFD value
    0.000000000063 /h
  • Safety parameters, Safety Integrity Level (SIL)
    3
  • SAP, basic quantity unit
    Piece
  • SAP, EAN (European Article Number)
    4030661472256
  • SAP, product group
    Initial
  • SAP, gross weight
    160.400 g
  • SAP, net weight
    160.400 g
  • Included in delivery, number and type, general
    Actuator must be ordered separately.
  • Temperature, Ambient temperature[generated product variant]
    -28 ... +70 °C
  • Temperature, ambient temperature, maximum
    70 °C
  • Temperature, ambient temperature, minimum
    -28 °C
  • Temperature, storage and transport temperature,[generated product variant]
    -28 ... +85 °C
  • Temperature, storage and transport temperature, maximum
    85 °C
  • Temperature, storage and transport temperature, minimum
    -28 °C
  • Time, Duration of risk, maximum
    200 ms
  • Time, Reaction, maximum
    100 ms
  • Tolerance, operating voltage, DC, maximum
    10 %
  • Tolerance, operating voltage, DC, minimum
    -15 %
  • Voltage, voltage drop Ud, maximum
    1 V
  • Voltage, Rated impulse withstand voltage
    0.8 kV
  • Voltage, rated insulation voltage
    32 VDC
  • Voltage, rated operating voltage
    24 VDC
  • Voltage, type
    DC
  • Voltage, Utilisation category DC-12, Fail-safe digital output
    24 VDC
  • Voltage, Utilisation category DC-13, Fail-safe digital output
    24 VDC
  • Web Type
    Product range
  • Selection (yes/no), cascadable
    Yes
  • Selection (Yes/No), Short-circuit recognition
    Yes
  • Selection (Yes/No), EPLAN
    Yes
  • Selection (Yes/No), Safety functions
    Yes
  • Selection (Yes/No), Integral System Diagnostics, status
    Yes
  • Selection (Yes/No), Short circuit detection
    Yes
  • Selection (Yes/No), Traceparts
    Yes
  • Current, Utilisation category DC-12, Diagnostic output
    0.05 A
  • Current, Utilisation category DC-13, Diagnostic output
    0.05 A
  • Type of execution, switching output, diagnostic output, electric
    p-type
  • Electrical data, Utilisation category DC-12, Diagnostic output [generated product variant]
    24 VDC / 0.05 A
  • Number, Semi-conductor outputs with signaling function
    1
  • Voltage, Utilisation category DC-12, Diagnostic output
    24 VDC
  • Voltage, Utilisation category DC-13, Diagnostic output
    24 VDC
  • Coding, Coding level according to EN ISO 14119
    High
  • Type of application, Actuating panel
    front side
    rear
    from head
  • Current, Required rated short-circuit current to EN 60947-5-1
    100 A
  • Type of Execution, Active area
    lateral
    front side
    cover-side
  • Height, Sensor
    30 mm
  • Width, Sensor
    52 mm
  • Standard, EMC rating
    IEC 60947-3
  • Standard, interfering radiation
    IEC 61000-6-4
  • Notes, length, sensor chain
    Cable length and cross-section change the voltage drop depen
  • Number, LED's
    2
  • Selection (Yes/No), Diagnostic output
    Yes
  • Note, series connection, sensors
    Unlimited number of devices, oberserve external line fusing,
  • Voltage, rated operating voltage, maximum
    26.4 VDC
  • Voltage, rated operating voltage, minimum
    20.4 VDC
  • Type of application, Relative humidity, maximum
    93 %
  • Coding, general information
    Individual coding
  • Current, consumption, Safety inputs
    5 mA
  • Current, Operating current, minimum
    0.5 mA
  • Type of execution, mounting
    2 x M5, Cylinder head screw
  • Height, permissible installation height above sea level, maximum
    2000 m
  • Note, Relative humidity
    non-condensing
    non-icing
  • Safety values, PFD value
    0.000015
  • Time, Switching frequency, maximum
    1 Hz
  • Time, Time to readiness, maximum
    2000 ms
  • Selection (Yes/No), CADENAS
    Yes
  • Selection (Yes/No), Series-wiring
    Yes
  • Current, Rated operating current, diagnostic output
    50 mA
  • Type of Execution, Cable entry
    4 x M16 x 1,5
  • Torque, tightening torque, screw, mounting
    2 Nm
  • This product is unavailable

    This product is currently unavaliable, this could be due to a limited stock shortage, or because of discontinuation or replacement. For more information please contact us at b2b@tipteh.si.

  • Manufacturer Schmersal