RSS260-SD-LSTM12-8-025M Electronic machine safety sensor

RSS260-SD-LSTM12-8-025M
Universal coding with RFID technology
Frontal and lateral actuation enabled
Max. 31 sensors can be wired in series.
serial diagnostic output
Thermoplastic enclosure
Simple mounting without additional angle
RFID-technology for needs-based protection against tampering
  • SKU
    4030661512167
  • Manufacturer code
    103025087
  • Current, Residual current, Fail-safe output, maximum
    0.5 mA
  • Current, Rated operating current
    600 mA
  • Current, Rated operating current, Safe digital outputs
    250 mA
  • Current, output current, fail-safe output, maximum
    0.25 A
  • Current, Utilisation category DC-12, Fail-safe digital output
    0.25 A
  • Current, Utilisation category DC-13, Fail-safe digital output
    0.25 A
  • Type of Execution, for degree of pollution VDE 0100
    3
  • Type of Execution, Housing construction form
    Block
  • Type of Execution, Terminals, mechanical
    not flush
  • Type of Execution, IP Protection class, General
    IP67
    IP65
  • Type of Execution, Overvoltage category VDE 0100
    3
  • Type of Execution, Overvoltage category IEC/EN 60664-1
    III
  • Type of execution, sensor, topology
    Sensor for series wiring
  • Type of execution, switching output, fail-safe output, electric
    short-circuit proof, p-type
  • Distance, Hysteresis, Mechanical, maximum
    2 mm
  • Distance, Repeat accuracy R R
    0.5 mm
  • Length, Sensor
    29.5 mm
  • Electrical data, Connector 1, Pin assignment, PIN 1
    A1 Ue: White
  • Electrical data, Connector 1, Pin assignment, PIN 2
    X1 safety input 1: Brown
  • Electrical data, Connector 1, Pin assignment, PIN 3
    A2 GND: Green
  • Electrical data, Connector 1, Pin assignment, PIN 4
    Y1 safety output 1: Yellow
  • Elektrische Daten, Absicherung des Sicherheitsausganges, Allgemein
    short-circuit proof, p-type
  • Material, active area
    Glass-fibre, thermoplastic
  • Housing material
    Plastic, thermoplastic, self-extinguishing
  • Standard, standards
    EN IEC 61508
    EN IEC 60947-5-3
    EN ISO 13849-1
  • Note, General
    Evaluation requirements: dual-channel safety input, suitable
  • Note, LED switching conditions display
    LED red: Fault
    LED yellow: Operating condition
    (1) LED green: Supply voltage
  • Number, fail-safe digital outputs
    2
  • Number, Series-wiring of sensors
    31
  • PIM maintenance status
    Discharge "Online catalog"
  • PNV, standard, certificates
    cULus
    TÜV
    UKCA
    FCC
    IC
    ANATEL
  • Recommendation, actuator
    RST16-1
    RST-U-2
    RST260-1
  • Recommended, Safety switchgear
    PROTECT PSC1
    SRB-E-301ST
    SRB-E-201LC
  • Type of electric connection
    Connector M12, 8-pole, A-coded
  • Review, Resistance to vibrations to EN 60068-2-6
    10 … 55 Hz, amplitude 1 mm
  • Review, restistance to shock
    30 g / 11 ms
  • Safety parameters, Category, EN ISO 13849
    4
  • Safety parameters, Mission time
    20 Year(s)
  • Safety parameter
    EN IEC 61508
    EN ISO 13849-1
  • Performance Level
    e
  • Safety values, PFD value
    0.00000000068 /h
  • Safety parameters, Safety Integrity Level (SIL)
    3
  • SAP, basic quantity unit
    Piece
  • SAP, EAN (European Article Number)
    4030661512167
  • SAP, product group
    Initial
  • SAP, gross weight
    121.000 g
  • SAP, net weight
    121.000 g
  • Included in delivery, number and type, general
    Actuator must be ordered separately.
  • Temperature, Ambient temperature[generated product variant]
    -28 ... +65 °C
  • Temperature, ambient temperature, maximum
    65 °C
  • Temperature, ambient temperature, minimum
    -28 °C
  • Temperature, storage and transport temperature,[generated product variant]
    -28 ... +85 °C
  • Temperature, storage and transport temperature, maximum
    85 °C
  • Temperature, storage and transport temperature, minimum
    -28 °C
  • Time, Duration of risk, maximum
    200 ms
  • Time, Reaction, maximum
    100 ms
  • Tolerance, operating voltage, DC, maximum
    10 %
  • Tolerance, operating voltage, DC, minimum
    -15 %
  • Voltage, voltage drop Ud, maximum
    1 V
  • Voltage, Rated impulse withstand voltage
    0.8 kV
  • Voltage, rated insulation voltage
    32 VDC
  • Voltage, rated operating voltage
    24 VDC -15% / +10%
  • Voltage, rated operating voltage
    24 VDC
  • Voltage, type
    DC
  • Voltage, Utilisation category DC-12, Fail-safe digital output
    24 VDC
  • Voltage, Utilisation category DC-13, Fail-safe digital output
    24 VDC
  • Web Type
    Product range
  • Selection (yes/no), cascadable
    Yes
  • Selection (Yes/No), Short-circuit recognition
    Yes
  • Selection (Yes/No), EPLAN
    Yes
  • Selection (Yes/No), Safety functions
    Yes
  • Selection (Yes/No), Integral System Diagnostics, status
    Yes
  • Selection (Yes/No), Short circuit detection
    Yes
  • Selection (Yes/No), Traceparts
    Yes
  • Electrical data, Connector 1, Pin assignment, PIN 5
    serial diagnostic output OUT Grey
  • Coding, Coding level according to EN ISO 14119
    Low
  • Electrical data, Connector 1, Pin assignment, PIN 6
    X2 safety input 2: Pink
  • Electrical data, Connector 1, Pin assignment, PIN 7
    Y2 safety output 2: Blue
  • Electrical data, Connector 1, Pin assignment, PIN 8
    IN serial diagnostic input Pink
  • Type of application, Actuating panel
    lateral
    front side
  • Current, Required rated short-circuit current to EN 60947-5-1
    100 A
  • Type of Execution, Active area
    lateral
    front
  • Height, Sensor
    18 mm
  • Width, Sensor
    39.2 mm
  • Standard, EMC rating
    IEC 60947-3
  • Standard, interfering radiation
    IEC 61000-6-4
  • Note, Distance, Repeat accuracy R
    Axial offset: The long side allows for a maximum height misa
  • Notes, length, sensor chain
    Cable length and cross-section change the voltage drop depen
  • Number, LED's
    3
  • Note, series connection, sensors
    Unlimited number of devices, oberserve external line fusing,
  • Voltage, rated operating voltage, maximum
    26.4 VDC
  • Voltage, rated operating voltage, minimum
    20.4 VDC
  • Type of application, Relative humidity, maximum
    93 %
  • Safety parameters, Coding levels according to EN ISO 14119  [generated product range]
    I1 variant: High
    I2 variant: High
    Standard coded v
  • Coding, general information
    Universal coding
  • Current, consumption, Safety inputs
    5 mA
  • Current, Operating current, minimum
    0.5 mA
  • Current, operation current, serial diagnostic SD[generated product range]
    150 mA
  • Type of Execution, IP Protection class, General  [generated product range]
    IP65, IP67
  • Type of execution, mounting
    A 20 mm screw length usually suffices to mount the sensor. W
  • Type of execution, mounting, Screws
    2x M4
  • Height, permissible installation height above sea level, maximum
    2000 m
  • Electrical data, Classification, ZVEI CB24I: Sink, Safety digital inputs
    C1
  • Electrical data, Classification, ZVEI CB24I: Sink, fail-safe digital outputs
    C1
    C2
  • Electrical data, Classification, ZVEI CB24I: Source, Safety digital inputs
    C1
    C2
    C3
  • Electrical data, Classification, ZVEI CB24I: Source, fail-safe digital outputs
    C2
  • Electrical data, Designation device connection, Safety inputs
    X1 and X2
  • Electrical data, Designation device connection, Safety outputs
    Y1 and Y2
  • Electrical data, Fuse rating, General
    short-circuit proof, p-type
  • Electrical data, Fuse rating, Current, maximum
    2 A
  • Electrical data, wiring capacity, serial diagnostic SD, maximum[generated product range]
    50 nF
  • Standard, standards [generated product range]
    EN ISO 13849-1, EN IEC 60947-5-3, EN IEC 61508
  • Note, Relative humidity
    non-condensing
    non-icing
  • Note, operating voltage, DC
    stabilised PELV power supply
  • Power, transmit, RFID, maximum
    -6 dB/m
  • Safety values, PFD value
    0.00012
  • Time, frequency band, RFID
    125 kHz
  • Time, Reaction, Actuator, maximum
    100 ms
  • Time, Switching frequency, maximum
    1 Hz
  • Time, test pulse duration, maximum
    1 ms
  • Time, test pulse duration, safety, digital output, maximum
    1 ms
  • Time, test pulse interval, safety digital input, minimum
    100 ms
  • Time, test pulse interval, safety digital output, typical
    1000 ms
  • Time, Time to readiness, maximum
    2000 ms
  • Torque, tightening torque, screw, mounting, maximum
    0.8 Nm
  • Selection (Yes/No), CADENAS
    Yes
  • Selection (Yes/No), Series-wiring
    Yes
  • Area, ensured switch distance OFF Sar, Front
    18 mm
  • Ensured switching distance "OFFF", side
    15 mm
  • Area, ensured switch distance ON Sao, Front
    10 mm
  • Area, ensured switch distance ON Sao, lateral
    6 mm
  • Range, switch distance S, typical, front
    12 mm
  • Range, switch distance S, typical, side
    9 mm
  • Notice, Switch distance Sn
    Axial misalignment, a horizontal and vertical misalignment o
  • Note, ensured switch distance ON Sao
    The specifications of the safety switching distance Sao refer to a temperature range of
    -10 °C ... +60 °C. For a temperature range of -28 °C ... +65 °C, Sao is reduced by 2 mm.
  • Number, poles
    8
  • Current, operation current, serial diagnostic SD
    150 mA
  • Type of execution, switching output, seriel diagnostic SD, electric
    short-circuit proof
  • Electrical data, Designation device connection, SD interface
    OUT
  • Electrical data, wiring capacity, serial diagnostic SD, maximum
    50 nF
  • Selection (Yes/No), Serial diagnostics
    Yes