Simple mounting without additional angle Universal coding with RFID technology Frontal and lateral actuation enabled RFID-technology for needs-based protection against tampering 8- pole cable connector M12 Thermoplastic enclosure
SKU
4030661500614
Manufacturer code
103013285
Current, Residual current, Fail-safe output, maximum
0.5 mA
Current, Rated operating current
600 mA
Current, Rated operating current, Safe digital outputs
250 mA
Current, output current, fail-safe output, maximum
0.25 A
Current, Utilisation category DC-12, Fail-safe digital output
0.25 A
Current, Utilisation category DC-13, Fail-safe digital output
0.25 A
Type of Execution, for degree of pollution VDE 0100
3
Type of Execution, Housing construction form
Block
Type of Execution, Terminals, mechanical
not flush
Type of Execution, IP Protection class, General
IP67
IP65
Type of Execution, Overvoltage category VDE 0100
3
Type of Execution, Overvoltage category IEC/EN 60664-1
III
Type of execution, sensor, topology
Sensor for series wiring
Type of execution, switching output, fail-safe output, electric
Axial misalignment, a horizontal and vertical misalignment o
Note, ensured switch distance ON Sao
The specifications of the safety switching distance Sao refer to a temperature range of -10 °C ... +60 °C. For a temperature range of -28 °C ... +65 °C, Sao is reduced by 2 mm.