Functions: Start/restart interlock (RES), Automatic start/restart, Static contactor monitoring (EDM), Stop function according to category Stop 0; Restart: Automatic, Manual; SIL: 3, IEC 61508; Performance Level (PL): Up to and including e, EN ISO 13849-1; Category: Up to and including 4: 1 sensor connected, EN ISO 13849; STOP category: 0, IEC/EN 60204-1; Contacts (NO contact/NC contact): 1 NO contact / 1 NC contact; Number of safety-related switching outputs (OSSDs): 2 Piece(s); Number of switching outputs: 1 Piece(s); Safety-related switching output 1: Relay, NO; Safety-related switching output 2: Relay, NO; Switching output 1: Relay, NC; Response time: 20 ms; Connection: Screw terminal; Dimension: 22.5 mm x 99 mm x 113.6 mm; Ambient temperature, operation: 0 ... 55 °C; Certifications: TÜV Süd, c UL US
-
SKU2110-549941
-
Manufacturer code549941
-
Type of electric connectionClip connection
-
Voltage type for actuatingAC/DC
-
Width22.5 mm
-
Height99 mm
-
Depth113.6 mm
-
Category according to EN 954-14
-
SIL according to IEC 615083
-
Performance level acc. EN ISO 13849-1Level e
-
Suitable for monitoring of emergency-stop circuitsNO
-
Suitable for monitoring of valvesNO
-
Suitable for monitoring of optoelectronic protection equipmentYES
-
Suitable for monitoring of tactile sensorsNO
-
Suitable for monitoring of proximity switchesNO
-
Rail mounting possibleYES
-
Evaluation inputsOther
-
With start inputYES
-
With feedback circuitYES
-
With approval for TÜVYES
-
With approval according to ULYES
-
Suitable for monitoring of magnetic switchesNO
-
With detachable clampsNO
-
Number of outputs, safety related, undelayed, semiconductors2
-
Stop category acc. IEC 602040
-
ModelBasic device
-
With muting functionNO
-
Type of safety acc. IEC 61496-1None
-
With approval for BG BIANO
-
Release-delay0.02 - 0.02 min
-
Manufacturer Leuze
-