Functions: Start/restart interlock (RES); Restart: Automatic, Manual; Type: 4, IEC/EN 61496; SIL: 3, IEC 61508; Performance Level (PL): Up to and including e, EN ISO 13849-1; Category: 4, EN ISO 13849; Contacts (NO contact/NC contact): 2 NO contacts / 2 NC contacts; Number of safety-related switching inputs: 2 Piece(s); Number of switching inputs: 2 Piece(s); Number of safety-related switching outputs (OSSDs): 2 Piece(s); Number of switching outputs: 3 Piece(s); Safety-related switching output 1: Relay, NO; Safety-related switching output 2: Relay, NO; Switching output 1: Transistor, PNP; Response time: 30 ms; Sensor response time on test request: 0.5 ... 8.5 ms; Connection: Screw terminal; Dimension: 22.5 mm x 99 mm x 114.1 mm; Ambient temperature, operation: -25 ... 55 °C; Certifications: c UL US
-
SKU2110-547931
-
Manufacturer code547931
-
Type of electric connectionClip connection
-
Voltage type for actuatingDC
-
Width22.5 mm
-
Height99 mm
-
Depth114.1 mm
-
Category according to EN 954-14
-
SIL according to IEC 615083
-
Performance level acc. EN ISO 13849-1Level e
-
Suitable for monitoring of emergency-stop circuitsNO
-
Suitable for monitoring of valvesNO
-
Suitable for monitoring of optoelectronic protection equipmentYES
-
Suitable for monitoring of tactile sensorsNO
-
Suitable for monitoring of proximity switchesNO
-
Rail mounting possibleYES
-
Evaluation inputsOther
-
With start inputYES
-
With feedback circuitYES
-
With approval for TÜVNO
-
With approval according to ULYES
-
Suitable for monitoring of magnetic switchesNO
-
With detachable clampsNO
-
Number of outputs, safety related, undelayed, semiconductors2
-
Stop category acc. IEC 60204Other
-
ModelBasic device
-
With muting functionNO
-
Type of safety acc. IEC 61496-14
-
With approval for BG BIANO
-
Release-delay0.03 - 0.03 min
-
Manufacturer Leuze
-