SIL: 3, IEC 61508; Performance Level (PL): e, EN ISO 13849-1; Category: 4, EN ISO 13849; STOP category: 0, IEC/EN 60204-1; Response time: 10 ms; Contacts (NO contact/NC contact): 3 NO contacts / 1 NC contact; Number of safety-related switching outputs (OSSDs): 3 Piece(s); Safety-related switching output 1: Relay, NO; Safety-related switching output 2: Relay, NO; Safety-related switching output 3: Relay, NO; Connection: Screw terminal; Dimension: 22.5 mm x 99 mm x 114.1 mm; Ambient temperature, operation: 0 ... 55 °C; Certifications: c TÜV NRTL US, TÜV Süd, c UL US; Functions: Cross circuit monitoring, Start/restart interlock (RES), selectable, Automatic start/restart, Contactor monitoring (EDM); Restart: Automatic, Manual
-
SKU2110-547950
-
Manufacturer code547950
-
Type of electric connectionClip connection
-
Width22.5 mm
-
Height99 mm
-
Depth114.1 mm
-
Category according to EN 954-14
-
SIL according to IEC 615083
-
Performance level acc. EN ISO 13849-1Level e
-
Suitable for monitoring of emergency-stop circuitsNO
-
Suitable for monitoring of valvesNO
-
Suitable for monitoring of optoelectronic protection equipmentYES
-
Suitable for monitoring of tactile sensorsNO
-
Suitable for monitoring of proximity switchesNO
-
Rail mounting possibleYES
-
Evaluation inputsOther
-
With start inputYES
-
With feedback circuitYES
-
With approval for TÜVYES
-
With approval according to ULYES
-
Suitable for monitoring of magnetic switchesNO
-
With detachable clampsNO
-
Number of outputs, safety related, undelayed, semiconductors3
-
Stop category acc. IEC 602040
-
ModelBasic device
-
With muting functionNO
-
Type of safety acc. IEC 61496-1None
-
With approval for BG BIANO
-
Release-delay0.01 - 0.01 min
-
Manufacturer Leuze
-