SFB-EIP-8M12-IOP Machine safety signal processing accessory

SFB-EIP-8M12-IOP
Safety fieldbox for EtherNet/IP with CIP-Safety
For connection of up to 8 safety switching devices
Integrated dual-port switch
Protection class IP66, IP67
  • SKU
    4030661628691
  • Manufacturer code
    103015480
  • Type of application, Relative humidity [generated produtct variant]
    10 ... 95 %
  • Type of application, Relative humidity, maximum
    95 %
  • Type of application, Relative humidity, minimum
    10 %
  • Current, Rated operating current
    10000 mA
  • Type of Execution, IP Protection class, General
    IP67
    IP66
  • Type of Execution, Overvoltage category IEC/EN 60664-1
    III
  • Type of Execution, Protection class (Operating resource)
    3
  • Height, General
    36.1 mm
  • Width, General
    63.0 mm
  • Material, housing
    Thermoplastic, Polyamide PA 6 GF
  • Note, Relative humidity
    non-condensing
  • Note, operating voltage, DC
    stabilised PELV power supply
  • PIM maintenance status
    Discharge "Online catalog"
  • SAP, basic quantity unit
    Piece
  • SAP, EAN (European Article Number)
    4030661628691
  • SAP, product group
    Initial
  • SAP, gross weight
    649.150 g
  • SAP, net weight
    649.150 g
  • Temperature, Ambient temperature[generated product variant]
    -25 ... +55 °C
  • Temperature, ambient temperature, maximum
    55 °C
  • Temperature, ambient temperature, minimum
    -25 °C
  • Temperature, storage and transport temperature,[generated product variant]
    -25 ... +70 °C
  • Temperature, storage and transport temperature, maximum
    70 °C
  • Temperature, storage and transport temperature, minimum
    -25 °C
  • Tolerance, operating voltage, DC, maximum
    10 %
  • Tolerance, operating voltage, DC, minimum
    -15 %
  • Voltage, Rated impulse withstand voltage
    0.8 kV
  • Voltage, rated insulation voltage
    32 VDC
  • Voltage, rated operating voltage
    24 VDC
  • Voltage, type
    DC
  • Length, General
    222.8 mm
  • Web Type
    Product range
  • Electrical data, Terminal, Connector, Transmitter, General
    M12 Connector socket/connector
  • Standard, standards
    EN ISO 13849-1
    EN IEC 60947-5-3
    EN IEC 61508
    EN IEC 61131-1
    EN IEC 61131-2
  • PNV, standard, certificates
    cULus
    TÜV
    UKCA
    ODVA
  • Review, Resistance to vibrations to EN 60068-2-6
    10 … 150 Hz, amplitude 0.35 mm / 5 g
  • Review, restistance to shock
    30 g / 11 ms
  • Safety parameter
    EN IEC 61508
    EN ISO 13849-1
  • Current, Consumption
    200 mA
  • Current, consumption at 24V, Diagnostic inputs / Fieldbox-Interface
    12 mA
  • Current, consumption at 24V, safety inputs
    6 mA
  • Current, Residual current, Test pulse output, maximum
    0.5 mA
  • Current, Permissible residual current, Safety digital inout, maximum
    1 mA
  • Current, Residual current, Fail-safe output, maximum
    0.5 mA
  • Current, Rated operating current, Pulse output Y2, at 0V
    30 mA
  • Current, Rated operating current, Pulse output Y1, at 24V
    15 mA
  • Current, Rated operating current, Pulse output Y2, at 24V
    10 mA
  • Current, Rated operating current, external devices
    800 mA
  • Current, Utilisation category DC-12, Fail-safe digital output
    0.8 A
  • Current, Utilisation category DC-13, Fail-safe digital output
    0.8 A
  • Type of Execution, Communication, Protocol, Fieldbus properties
    Device Level Ring (DLR)
  • Type of Execution, Communication, Protocol, Fieldbus
    EtherNet/IP / CIP Safety
  • Type of Execution, Communication, Protocol, Fieldbus services
    LLDP
  • Type of Execution, Communication, Protocol, Fieldbus specification
    V1.27
  • Type of Execution, Communication, Protocol, Safety Flieldbus Specification
    V2.22
  • Type of Execution, Communication, Protocol, Integrated switch
    Dual Port, 100 Mbit/s
  • Type of Execution, Communication, Protocol, IP adressing
    Dynamic Host Configuration Protocol (DHCP) / BootP
  • Type of Execution, Communication, Protocol, Transfer rate
    100 Mbit/s Full Duplex
  • Type of Execution, Communication, Protocol, Transfer rate, Diagnostic inputs / Fieldbox-Interface
    19,2 kBaud
  • Type of Execution, Communication, Protocol, Service interface
    WEB-Interface HTTP
  • Type of Execution, Degree of pollution IEC/EN 60664-1
    3
  • Type of execution, mounting
    Screws
  • Type of execution, mounting, Screws
    2x M6
  • Type of execution, mounting, screws, viewing window
    2x TX10 (Torx)
  • Type of execution, switching output, fail-safe output, electric
    short-circuit proof, p-type
  • Type of execution, switching output, test pulse output, electric
    short-circuit proof, p-type
  • Height, permissible installation height above sea level, maximum
    2000 m
  • Length, Cable, Device Port, maximum
    30 m
  • Electrical data, Classification, ZVEI CB24I: Sink, Test pulse outputs
    C1
  • Electrical data, Classification, ZVEI CB24I: Sink, Safety digital inputs
    C1
  • Electrical data, Classification, ZVEI CB24I: Sink, fail-safe digital outputs
    C1
  • Electrical data, Classification, ZVEI CB24I: Source, Test pulse outputs
    C1
  • Electrical data, Classification, ZVEI CB24I: Source, Safety digital inputs
    C1
    C2
    C3
  • Electrical data, Classification, ZVEI CB24I: Source, fail-safe digital outputs
    C1
  • Electrical data, Designation device connection, Diagnostic inputs / Fieldbox-Interface
    DI
  • Electrical data, Designation device connection, general
    X0 ... X7
  • Electrical data, Designation device connection, Test pulse outputs
    Y1 and Y2
  • Electrical data, Designation device connection, Power supply
    A1 and A2
  • Electrical data, Designation device connection, Safety inputs
    X1 and X2
  • Electrical data, Designation device connection, Safety outputs
    DO
  • Electrical data, Internal fuse rating, External devices
    1.5 A (Integrated automatic resettable fuse)
  • Electrical data, Inputs, Switching thresholds, Diagnostic inputs / Fieldbox-Interface
    −3 V … 5 V (Low)
    15 V … 30 V (High)
  • Electrical data, inputs, switching thresholds for fail-safe inputs
    13 V ... 30 V (High)
    −3 V … 5 V (Low)
  • Electrical data, Terminal Connector, Field bus
    M12, 4-pole, D-coded
  • Electrical data, Terminal connector, Input/Output
    X0 - X7: M12, 8-pole, A-coded
  • Electrical data, Terminal Connector, Power I/O
    M12 POWER, 4-pole, T-coded
  • Material, identification label
    Plastic, Polyamide PA
  • Material, Encapsulation (electronic)
    Polyurethane 2K PU
  • Material, Inspection window
    Polyamide PACM 12
  • Note, Electrical data, Fuse rating)
    External fuse protection required ≤ 10A slow blow when used
  • Notice, Safety parameters, 2-channel safety inputs
    The SFB fulfils the requirements as PDDB (proximity switch w
  • Note, applications
    Safe field box with decentralised I/Os
  • Note, Utilisation category DC-13, Fail-safe digital output
    Inductive load, maximum 400 mH
  • Safety parameters, Category, EN ISO 13849, 1 channel Inputs
    2
  • Safety parameters, Category, EN ISO 13849, Outputs with 1x cable
    3
  • Safety parameters, Category, EN ISO 13849, 2 channel Inputs
    4
  • Safety parameters, Category, EN ISO 13849, Outputs with 2x cable
    4
  • Safety parameters Diagnostic Coverage (DC) Level, 1 channel Inputs
    90 %
  • Sicherheitskennwerte, Diagnostic Coverage (DC) Level, Ausgänge mit 1x Leitung
    90 %
  • Safety parameters Diagnostic Coverage (DC) Level, 2 channel Inputs
    99 %
  • Sicherheitskennwerte, Diagnostic Coverage (DC) Level, Ausgänge mit 2x Leitung
    99 %
  • Safety parameters, Mission time, 1 channel Inputs
    20 Year(s)
  • Safety parameters, Mission time, Outputs with 1x cable
    20 Year(s)
  • Safety parameters, Mission time, 2 channel Inputs
    20 Year(s)
  • Safety parameters, Mission time, Outputs with 2x cable
    20 Year(s)
  • Safety parameters, Performance Level, 1-channel inputs
    d
  • Safety parameters, Performance Level, outputs with 1x cable
    d
  • Safety parameters, Performance Level, 2-channel inputs
    e
  • Safety parameters, Performance Level, outputs with 2x cable
    e
  • Safety parameters, PFDavg-value, 1-channel inputs
    0.02
  • Safety parameters, PFDavg-value, outputs with 1x cable
    0.0088
  • Safety parameters, PFDavg-value, 2-channel inputs
    0.000096
  • Safety parameters, PFDavg-values, outputs with 2x cable
    0.00011
  • Safety parameters, PFH-value, 1-channel inputs
    0.00000023 /h
  • Safety parameters, PFH-value, outputs with 1x cable
    0.0000001 /h
  • Safety parameters, PFH-value, 2-channel inputs
    0.0000000011 /h
  • Safety parameters, PFH-value, outputs with 2x cable
    0.0000000012 /h
  • Safety parameters, Safety Integrity Level (SIL), 1-channel inputs
    1
  • Safety parameters, Safety Integrity Level (SIL), outputs with 1x cable
    2
  • Safety parameters, Safety Integrity Level (SIL), 2-channel inputs
    3
  • Safety parameters, Safety Integrity Level (SIL), outputs with 2x cable
    3
  • Notice, Test interval for error detection
    10 s
  • Sicherheitskennwerte, Reaktionszeit, 1-kanalige Eingänge => Feldbussystem, maximum
    20 ms
  • Sicherheitskennwerte, Reaktionszeit, 2-kanalige Eingänge => Feldbussystem, maximum
    20 ms
  • Sicherheitskennwerte, Reaktionszeit, Feldbussystem => Ausgang mit 1x Leitung, maximum
    50 ms
  • Sicherheitskennwerte, Reaktionszeit, Feldbussystem => Ausgang mit 2x Leitung, maximum
    50 ms
  • Status display, LED 1, Colour
    green/red
  • Status display, LED 1, Information
    Error LED device port
  • Status display, LED 1, Position
    E: 0 ... 7
  • Status display, LED 2, Colour
    Yellow
  • Status display, LED 2, Information
    Input LED device port
  • Status display, LED 2, Position
    I: 0 ... 7
  • Status display, LED 3, Colour
    Green
  • Status display, LED 3, Information
    LED Link Ethernet port
  • Status display, LED 3, Position
    L: P1 + P2
  • Status display, LED 4, Colour
    Yellow
  • Status display, LED 4, Information
    LED Activity Ethernet port
  • Status display, LED 4, Position
    A: P1 + P2
  • Status display, LED 5, Colour
    green/red
  • Status display, LED 5, Information
    Module status LED
  • Status display, LED 5, Position
    "MS": Module
  • Status display, LED 6, Colour
    green/red
  • Status display, LED 6, Information
    Network Status LED
  • Status display, LED 6, Position
    "NS": Module
  • Status display, LED 7, Colour
    green/red
  • Status display, LED 7, Information
    Fieldbox error LED
  • Status display, LED 7, Position
    "Err": Module
  • Status display, LED 8, Colour
    Green
  • Status display, LED 8, Information
    Power-LED fieldbox
  • Status display, LED 8, Position
    "Pwr": Module
  • Time, Device Watchdog Time
    12 ms
  • Time, Debounce filter, Input, Diagnostic inputs / Fieldbox-Interface
    10 ms
  • Time, Switching frequency, Safety digital output, maximum
    1 Hz
  • Time, test pulse duration, safety, test pulse output, maximum
    1 ms
  • Time, test pulse duration, maximum
    1 ms
  • Time, test pulse duration, minimum
    0.01 ms
  • Time, test pulse duration, safety, digital output, maximum
    1 ms
  • Time, test pulse interval, test pulse output, typical
    500 ms
  • Time, test pulse interval, safety digital input, maximum
    120000 ms
  • Time, test pulse interval, safety digital input, minimum
    20 ms
  • Time, test pulse interval, safety digital output, maximum
    500 ms
  • Time, test pulse interval, safety digital output, minimum
    15 ms
  • Time, Time to readiness, maximum
    12000 ms
  • Time, Worst Case Delay Time, Inputs, maximum
    20 ms
  • Time, Worst Case Delay Time, Outputs, maximum
    50 ms
  • Tightening torque, tightening torque, Electrical connection[generated product variant]
    0.8 ... 1.5 Nm
  • Tightening torque, tightening torque, Electrical connection, maximum
    1.5 Nm
  • Torque, tightening torque, electrical connection, minimum
    0.8 Nm
  • Torque, tightening torque, screw, mounting, maximum
    3.0 Nm
  • Torque, tightening torque, cable gland, maximum
    0.6 Nm
  • Voltage, voltage drop Ud, maximum
    2 V
  • Voltage, rated operating voltage, external devices
    24 VDC
  • Voltage, Utilisation category DC-12, Test pulse output
    24 VDC
  • Voltage, Utilisation category DC-12, Fail-safe digital output
    24 VDC
  • Voltage, Utilisation category DC-13, Fail-safe digital output
    24 VDC
  • Selection (Yes/No), CADENAS
    Yes
  • Selection (Yes/No), EPLAN
    Yes
  • Selection (Yes/No), Integral System Diagnostics, general
    Yes
  • Selection (Yes/No), Traceparts