2 cable entries M 16 x 1.5 with fixed switching angle Metal enclosure Good resistance to oil and petroleum spirit For left or right hinged doors 141 mm x 115 mm x 21,5 mm Simple mounting, suitable for all conventional profile systems (30 … 60 mm)
SKU
4030661419008
Manufacturer code
101182693
CAD, traceparts, product ID
69-16012013-049056
Current, Thermal test current
2.5 A
Current, Utilisation category AC-15
2 A
Current, Utilisation category DC-13
1 A
Type of Execution, IP Protection class, General
IP65
Type of Execution, Mechanical life, minimum,
1000000 Operations
Switching principle
Slow action
Angle, Positive break angle
10 °
Height, Sensor
115 mm
Length, Sensor
21.5 mm
Width, Sensor
141 mm
Electrical data, Cable section, maximum
1 mm²
Electrical data, Cable section, minimum
0.5 mm²
Electrical data, Max. fuse rating
2 A gG D-fuse
Electrical data, Utilisation category
DC-13
AC-15
Material, contacts, electrical
Silver-nickel alloy 10
Housing material
Metal, zinc die-cast
Standard, standards
EN IEC 60947-5-1
BG-GS-ET-15
Note, Electrical Data, Cable section
All indications including the conductor ferrules.
Note, General
Closed guard device = 0° in contact switch travel diagrams.
The factory-set switching angle is 3°.
Until the limit of the mechanical life has been reached the
The positive break angle is 10°.