Already a member? Sign in or create an account

Cart

Product Quantity  

Your cart is empty.

AZM 170 B ST-AS RP Machine safety solenoid interlock

AZM 170 B ST-AS RP
Actuator monitored
Solenoid interlock
Integrated AS-Interface
Thermoplastic enclosure
90 mm x 84 mm x 30 mm
Double-insulated
High holding force
  • SKU
    4030661390413
  • Manufacturer code
    101210927
  • PIM maintenance status
    Discharge "Online catalog"
  • SAP, basic quantity unit
    Piece
  • SAP, EAN (European Article Number)
    4030661390413
  • SAP, product group
    Initial
  • SAP, gross weight
    285.000 g
  • SAP, net weight
    285.000 g
  • Web Type
    Product range
  • Type of Execution, IP Protection class, General
    IP67
  • Type of Execution, Mechanical life, minimum,
    1000000 Operations
  • Height, Sensor
    75.5 mm
  • Width, Sensor
    90 mm
  • Force, Latching force
    30 N
  • Housing material
    Plastic, glass-fibre reinforced thermoplastic, self-extingui
  • Movement, actuating speed, maximum
    2 m/s
  • Standard, standards
    EN IEC 60947-5-1
    EN ISO 13849-1
    EN IEC 61508
    EN IEC 62026-2
  • Note, Relative humidity
    non-condensing
    non-icing
  • Number, Actuating directions
    2
  • PNV, standard, certificates
    cULus
    TÜV
    ASi-SaW
  • Electrical data, Terminal, Connector, Transmitter, General
    Connector plug M12, 4-pole, (A-coding)
  • Safety parameters, Mission time
    20 Year(s)
  • Safety parameter
    EN IEC 61508
  • Included in delivery, number and type, general
    Actuator must be ordered separately.
  • Temperature, Ambient temperature[generated product variant]
    -25 ... +55 °C
  • Temperature, ambient temperature, maximum
    55 °C
  • Temperature, ambient temperature, minimum
    -25 °C
  • Voltage, Rated impulse withstand voltage
    0.8 kV
  • Voltage, rated insulation voltage
    32 VDC
  • Selection (Yes/No), Power to unlock
    Yes
  • Selection (Yes/No), Traceparts
    Yes
  • Type of Execution, Overvoltage category IEC/EN 60664-1
    II
  • Type of Execution, Protection class (Operating resource)
    2
  • Note, General
    Interlocks with the power to lock principle may only be used
  • Note, Safety parameters, Fault exclusion
    Can be used when fault exclusion for dangerous damage to the
  • Safety parameters, Category, EN ISO 13849
    1
  • Safety parameters, Category, EN ISO 13849, Fault exclusion
    3
  • Safety parameters, Mission time, Fault exclusion
    20 Year(s)
  • Safety parameters, Performance Level,
    c
  • Safety parameters, Performance Level, Fault exclusion
    d
  • Temperature, storage and transport temperature,[generated product variant]
    -25 ... +85 °C
  • Temperature, storage and transport temperature, maximum
    85 °C
  • Temperature, storage and transport temperature, minimum
    -25 °C
  • Selection (Yes/No), CADENAS
    Yes
  • Type of application, Relative humidity [generated produtct variant]
    30 ... 95 %
  • Type of application, Relative humidity, maximum
    95 %
  • Type of application, Relative humidity, minimum
    30 %
  • Type of Execution, for degree of pollution VDE 0100
    3
  • Type of Execution, Overvoltage category VDE 0100
    3
  • Note, LED switching conditions display
    (1) LED green: Supply voltage
    (3) LED yellow : Enabling status
    (2) red LED: Communication error / Slave address = 0
  • Time, Reaction, maximum
    100 ms
  • Selection (Yes/No), Integral System Diagnostics, status
    Yes
  • Selection (Yes/No), Actuator monitored
    Yes
  • Current, consumption, AS-i, maximum
    100 mA
  • Current, Consumption, External auxiliary voltage (AUX)
    500 mA
  • Electrical Data, Inputs, AS-i, Channel 1
    Data bits DI 0 / DI 1 = dynamic code transmission
  • Electrical Data, Inputs, AS-i, Channel 2
    Data bits DI 2 / DI 3 = dynamic code transmission
  • Electrical Data, AS-i, Input module address
    0
  • Electrical data, AS-i, Parameter bits, P0
    Safety guard and actuator detected
  • Electrical data, AS-i, Parameter bits, P1
    Solenoid interlock locked
  • Electrical data, AS-i, Parameter bits, P2
    No function
  • Electrical data, AS-i, Parameter bits, P3
    No function
  • Electrical data, AS-i, Profile
    S-7.B.F.E
  • Electrical Data, AS-i, Specification
    Safety-Slave
  • Electrical data, AS-i, Version
    V 2.1
  • Electrical data, Connector, AS-i, PIN 1
    AS-i +
  • Electrical data, Connector, AS-i, PIN 2
    Aux - (P)
  • Electrical data, Connector, AS-i, PIN 3
    AS-Interface -
  • Electrical data, Connector, AS-i, PIN 4
    Aux + (P)
  • Electrical Data, Device protection, AS-i
    Internal short-circuit proof
  • Elektrische Daten, Absicherung der Hilfspannung (AUX), Strom, maximum
    4 A
  • Electrical data, Outputs, AS-i, DO 0
    Solenoid control
  • Electrical data, Outputs, AS-i, DO 1
    No Function
  • Electrical data, Outputs, AS-i, DO 2
    No Function
  • Electrical data, Outputs, AS-i, DO 3
    No Function
  • Note, Electrical data, AS-i, Input module address
    Preset to address 0, can be changed through AS-interface bus
  • Note, Electrical data, AS-i, Parameter bits
    Set the parameter outputs to "1111" (0xF)
    FID: periphery error
  • Note, operating voltage, AS-i
    Protection against polarity reversal
  • Note, operating voltage, auxiliary voltage
    stabilised PELV power supply
  • Note, rated operating voltage, ASi
    Protection against polarity reversal
  • Review, Coding, AS-i, ID-Code
    0xB
  • Review, Coding, AS-i, ID-Code1
    0xF
  • Review, Coding, AS-i, ID-Code2
    0xE
  • Review, Coding, AS-i, IO-Code
    0x7
  • Safety values, PFD value
    0.00000116 /h
  • Safety parameters, Safety Integrity Level (SIL)
    1
  • Tolerance, operating voltage, auxiliary voltage, maximum
    10 %
  • Tolerance, operating voltage, auxiliary voltage, minimum
    -15 %
  • Voltage, Operating voltage, AS-i, maximum
    31.6 VDC
  • Voltage, Operating voltage, AS-i, minimum
    26.5 VDC
  • Voltage, rated operating voltage, ASi, maximum
    31.6 VDC
  • Voltage, rated operating voltage, ASi, minimum
    26.5 VDC
  • Voltage, Rated operating voltage, Auxiliary voltage (AUX)
    24 VDC -15% / +10% (stabilised PELV)
  • Voltage, rated operating voltage, auxiliary voltage
    24 VDC
  • Voltage, type, ASi
    DC
  • Voltage, type, auxiliary voltage
    DC
  • Note, Safety Parameters, PFH-value
    up to max. 100,000 switching cycles/year
  • Note, Safety Parameters, PFH-value, Fault exclusion
    up to max. 100,000 switching cycles/year
  • Safety parameters, PFH value, Fault exclusion
    0.000000101 /h
  • Force, clamping force
    1000 N
  • This product is unavailable

    This product is currently unavaliable, this could be due to a limited stock shortage, or because of discontinuation or replacement. For more information please contact us at b2b@tipteh.si.

  • Manufacturer Schmersal