BDF200-FB-B-LT-SWS20-B-2875 Enabling device

BDF200-FB-B-LT-SWS20-B-2875
slender shock-proof thermoplastic enclosure
to be installed at an ergonomic favourable position
to be fitted to commercial-off-the-shelf aluminium profiles
E-STOP with electronic OSSDs
  • SKU
    4030661563442
  • Manufacturer code
    103044610
  • Type of Execution, Terminals, mechanical
    Connector plug M12, 8-pole, A-coded
  • Type of Execution, for degree of pollution VDE 0100
    3
  • Type of Execution, IP Protection class, General
    IP65
  • Design, Mechanical Life, Command devices
    1000000 Operations
  • Design, Mechanical Life, Emergency-Stop button
    100000 Operations
  • Type of execution, mounting
    interior mounting holes
  • Type of execution, mounting, Screws
    2x M5
  • Type of Execution, Overvoltage category IEC/EN 60664-1
    III
  • Depth, General
    220 mm
  • Height, General
    69 mm
  • Width, General
    40 mm
  • Housing material
    Plastic, glass-fibre reinforced thermoplastic, self-extingui
  • Standard, climatic stress
    DIN EN 60068
  • Standard, standards
    EN IEC 60947-5-1
    EN IEC 60947-5-5
    EN ISO 13850
    EN ISO 13849-1
    EN IEC 61508
  • Note, Ordering data
    Notice: see ordering code
  • PIM maintenance status
    Discharge "Online catalog"
  • Review, Resistance to vibrations to EN 60068-2-6
    10 … 150 Hz, amplitude 0.35 mm / 5 g
  • Review, restistance to shock
    30 g / 11 ms
  • Safety parameters, Mission time
    20 Year(s)
  • Safety parameter
    EN ISO 13849-1
    EN IEC 61508
  • SAP, basic quantity unit
    Piece
  • SAP, EAN (European Article Number)
    4030661563442
  • SAP, product group
    Initial
  • SAP, gross weight
    280.000 g
  • SAP, net weight
    280.000 g
  • Temperature, Ambient temperature[generated product variant]
    -25 ... +65 °C
  • Temperature, ambient temperature, maximum
    65 °C
  • Temperature, ambient temperature, minimum
    -25 °C
  • Voltage, Rated impulse withstand voltage
    0.8 kV
  • Voltage, rated insulation voltage
    32 VDC
  • Voltage, rated operating voltage
    24 VDC
  • Web Type
    Product range
  • Selection (Yes/No), Safety functions
    Yes
  • Type of Execution, Overvoltage category VDE 0100
    3
  • Type of Execution, Protection class (Operating resource)
    3
  • Height, permissible installation height above sea level, maximum
    2000 m
  • Note, Safety Parameters, PFH-value
    up to max. 5,000 switching cycles/year
  • Safety parameters, Category, EN ISO 13849
    4
  • Safety parameters, Performance Level,
    e
  • Safety values, PFD value
    0.000000000289 /h
  • Safety parameters, Safety Integrity Level (SIL)
    3
  • Temperature, storage and transport temperature,[generated product variant]
    -25 ... +85 °C
  • Temperature, storage and transport temperature, maximum
    85 °C
  • Temperature, storage and transport temperature, minimum
    -25 °C
  • Time, Reaction, maximum
    50 ms
  • Selection (Yes/No), CADENAS
    Yes
  • Selection (Yes/No), Indicator lamp
    No
  • Selection (Yes/No), Traceparts
    Yes
  • Voltage, rated operating voltage
    24 VDC −15 % / +10 %
    (PELV to IEC 60204-1)
  • Voltage, type
    DC
  • Current, consumption at 24V, safety inputs
    5 mA
  • Current, Residual current, Fail-safe output, maximum
    0.5 mA
  • Current, operation current, serial diagnostic SD
    10 mA
  • Current, Rated operating current
    600 mA
  • Current, Required rated short-circuit current to EN 60947-5-1
    100 A
  • Current, Utilisation category DC-12, Fail-safe digital output
    0.25 A
  • Current, Utilisation category DC-13, Fail-safe digital output
    0.25 A
  • Type of execution, switching output, fail-safe output, electric
    short-circuit proof, p-type
  • Type of execution, switching output, seriel diagnostic SD, electric
    short-circuit proof, p-type
  • Electrical data, Classification, ZVEI CB24I: Sink, Safety digital inputs
    C1
  • Electrical data, Classification, ZVEI CB24I: Sink, fail-safe digital outputs
    C1
  • Electrical data, Classification, ZVEI CB24I: Source, Safety digital inputs
    C1
    C2
    C3
  • Electrical data, Classification, ZVEI CB24I: Source, fail-safe digital outputs
    C1
  • Electrical data, Connector 1, Pin assignment, PIN 1
    A1 Supply voltage UB
  • Electrical data, Connector 1, Pin assignment, PIN 2
    X1 Safety input 1
  • Electrical data, Connector 1, Pin assignment, PIN 3
    A2 GND
  • Electrical data, Connector 1, Pin assignment, PIN 4
    Y1 Safety output 1
  • Electrical data, Connector 1, Pin assignment, PIN 5
    OUT serial diagnostic output
  • Electrical data, Connector 1, Pin assignment, PIN 6
    X2 Safety input 2
  • Electrical data, Connector 1, Pin assignment, PIN 7
    Y2 Safety output 2
  • Electrical data, Connector 1, Pin assignment, PIN 8
    n.c.
  • Electrical data, Designation device connection, SD interface
    OUT
  • Electrical data, Designation device connection, Safety inputs
    X1 and X2
  • Electrical data, Designation device connection, Safety outputs
    Y1 and Y2
  • Electrical data, inputs, switching thresholds for fail-safe inputs
    −3 V … 5 V (Low)
    15 V … 30 V (High)
  • Electrical data, wiring capacity, serial diagnostic SD, maximum
    50 nF
  • Note, operating voltage, DC
    stabilised PELV power supply
  • Number, fail-safe digital outputs
    2
  • Review, general dimensions (length, width, height, etc.)
    Depth: 233.5 - 252.5 mm (without and with indicator lamp)
  • Time, Duration of risk, maximum
    100 ms
  • Time, Switching frequency, maximum
    1.0 Hz
  • Time, test pulse duration, maximum
    1 ms
  • Time, test pulse duration, safety, digital output, maximum
    1.0 ms
  • Time, test pulse interval, safety digital input, minimum
    100 ms
  • Time, test pulse interval, safety digital output, typical
    1000 ms
  • Time, Time to readiness, maximum
    2000 ms
  • Tolerance, operating voltage, DC, maximum
    10 %
  • Tolerance, operating voltage, DC, minimum
    -15 %
  • Voltage, voltage drop Ud, maximum
    1 V
  • Voltage, Utilisation category DC-12, Fail-safe digital output
    24 VDC
  • Voltage, Utilisation category DC-13, Fail-safe digital output
    24 VDC
  • Selection (Yes/No), Serial diagnostics
    No
  • This product is unavailable

    This product is currently unavaliable, this could be due to a limited stock shortage, or because of discontinuation or replacement. For more information please contact us at b2b@tipteh.si.

  • Manufacturer Schmersal

Related products