This is an unpolarized retro-reflective photoelectric sensor designed for use with glass triple reflectors and reflective tapes. It features autocollimation and offers versatile switching outputs.
SKU
2110-50117375
Manufacturer code
50117375
Pre failure notice
false
With time function
false
Rated switching distance
6000 mm
Max. switching distance
6000 mm
Max. output current
100 A
With reflector
false
Analogue output 0 V ... 10 V
false
Analogue output 0 mA ... 20 mA
false
Analogue output 4 mA ... 20 mA
false
Analogue output -10 V ... +10 V
false
With other analogue output
false
With communication interface analogue
false
With communication interface AS-Interface
false
With communication interface CANOpen
false
With communication interface DeviceNet
false
With communication interface Ethernet
false
With communication interface INTERBUS
false
With communication interface PROFIBUS
false
With communication interface RS-232
false
With communication interface RS-422
false
With communication interface RS-485
false
With communication interface SSD
false
With communication interface SSI
false
Number of semiconductor outputs with signalling function
2
Number of protected semiconductor outputs
0
Type of electric connection
Connector M12
Type of switching output
PNP
Type of switch function
Other
Operation agent-safety class
Safety class 3
Explosion safety category for gas
None
Explosion safety category for dust
None
Construction type housing
Cuboid
Width sensor
15 mm
Height of sensor
47 mm
Length of sensor
32.5 mm
Sensing mode
Light switching
Material of optical surface
Glass
Housing material
Metal
Metal
Metal
Metal
Min. reflector distance
0 mm
Ambient temperature
-40 - 60 °C
Response time
1 s
Switching frequency
500 Hz
Rated control supply voltage DC
10 - 30 V
Voltage type
DC
DC
DC
DC
With monitoring function downstream switching devices
false
Laser protection class
None
Wavelength of the sensor
620 nm
Type of light
Polarity free red light
With restart blockage
false
Suitable for safety functions
false
Degree of protection (IP)
IP67
Setting procedure
Manual adjustment
Most suitable applications
Operation with glass triple reflectors
Use with any reflective tapes