Already a member? Sign in or create an account

Cart

Product Quantity  

Your cart is empty.

AZM 161CC-12/12RKAN-024 Machine safety solenoid interlock

AZM 161CC-12/12RKAN-024
Large wiring compartment
Emergency release
cable entries 4 M 16 x 1.5
Thermoplastic enclosure
Double-insulated
Interlock with protection against incorrect locking.
130 mm x 90 mm x 30 mm
6 Contacts
Long life
  • SKU
    4030661317465
  • Manufacturer code
    101182428
  • Coding, Coding level according to EN ISO 14119
    Low
  • PIM maintenance status
    Discharge "Online catalog"
  • SAP, basic quantity unit
    Piece
  • SAP, EAN (European Article Number)
    4030661317465
  • SAP, product group
    Initial
  • SAP, gross weight
    420.000 g
  • SAP, net weight
    420.000 g
  • Web Type
    Product range
  • Current, Thermal test current
    6 A
  • Current, Utilisation category AC-15, Auxiliary contacts
    4 A
  • Current, Utilisation category AC-15, Safety contacts
    4 A
  • Current, Utilisation category DC-13, Auxiliary contacts
    2.5 A
  • Current, Utilisation category DC-13, Safety contact
    2.5 A
  • Type of Execution, Cable entry
    4 x M16 x 1,5
  • Type of Execution, IP Protection class, General
    IP67
  • Type of Execution, Mechanical life, minimum,
    1000000 Operations
  • Switching principle
    slow action, positive break NC contact
  • Height, permissible installation height above sea level, maximum
    2000 m
  • Height, Sensor
    90 mm
  • Length, Sensor
    30 mm
  • Width, Sensor
    130 mm
  • Electrical data, Cable section, maximum
    1.5 mm²
  • Electrical data, Cable section, minimum
    0.25 mm²
  • Electrical data, Max. fuse rating
    6 A gG D-fuse to DIN EN 60269-1
  • Force, clamping force in accordance with EN ISO 14119
    2000 N
  • Clamping force, maximum
    2600 N
  • Force, Latching force
    30 N
  • Force, Positive break force, minimum Force,
    20 N
  • Material, contacts, electrical
    Silver
  • Housing material
    Plastic, glass-fibre reinforced thermoplastic, self-extingui
  • Movement, actuating speed, maximum
    2 m/s
  • Standard, standards
    EN IEC 60947-5-1
    EN ISO 13849-1
    EN ISO 14119
  • Note, Electrical Data, Cable section
    All indications including the conductor ferrules.
  • Note, Relative humidity
    non-condensing
    non-icing
  • Number, Actuating directions
    3
  • Number, Auxiliary contacts
    2
  • Number, Safety contacts
    4
  • PNV, standard, certificates
    CCC
    cULus
  • Power, electrical consumption, maximum
    10 W
  • Type of switch function
    NO contact, NC contact
  • Electrical data, Terminal, Connector, Transmitter, General
    Cage clamps
  • Safety parameters, Mission time
    20 Year(s)
  • Safety parameter
    EN ISO 13849-1
  • Included in delivery, number and type, general
    Actuator must be ordered separately.
  • Temperature, Ambient temperature[generated product variant]
    -30 ... +60 °C
  • Temperature, ambient temperature, maximum
    60 °C
  • Temperature, ambient temperature, minimum
    -30 °C
  • Time, Switching frequency
    1000 /h
  • Time, duty cycle solenoid
    100 %
  • Time, test pulse duration, maximum
    5 ms
  • Time, test pulse interval, solenoid control, minimum
    50 ms
  • Voltage, Rated control voltage
    24 VAC/DC
  • Voltage, Rated impulse withstand voltage
    4 kV
  • Voltage, rated insulation voltage
    250 VAC
  • Voltage, Utilisation category AC-15, Auxiliary contacts
    230 VAC
  • Current, Utilisation category AC-15, Safety contact VAC}
    230 VAC
  • Voltage, Utilisation category DC-13, Auxiliary contacts
    24 VDC
  • Current, Utilisation category DC-13, Safety contact VDC}
    24 VDC
  • Selection (Yes/No), Power to lock
    Yes
  • Path, positive break travel
    10 mm
  • Note, applications
    sliding safety guard
    hinged safety guard
    removable guard
  • Selection (Yes/No), Traceparts
    Yes
  • Current, Required rated short-circuit current to EN 60947-5-1
    1000 A
  • Type of execution, mounting
    Screws
  • Type of execution, mounting, Screws
    3x M5
  • Type of Execution, Overvoltage category IEC/EN 60664-1
    II
  • Type of Execution, Protection class (Operating resource)
    2
  • Electrical data, Connector, allowed type of cable
    flexible
    solid single-wire
    solid multi-wire
  • Force, Positive break force per NC contact, minimum Force,
    10 N
  • Note, General
    Interlocks with the power to lock principle may only be used
  • Note, Safety parameters, B10d, Normally-open contact  (NO)
    at 10% Ie and ohmic load
  • Note, Safety parameters, Fault exclusion
    Can be used when fault exclusion for dangerous damage to the
  • Safety parameters, B10d, Normally-closed contact  (NC),
    2000000 Operations
  • Safety parameters, B10d, Normally-open contact (NO)
    1000000 Operations
  • Safety parameters, Category, EN ISO 13849
    1
  • Safety parameters, Category, EN ISO 13849, Fault exclusion
    3
  • Safety parameters, Mission time, Fault exclusion
    20 Year(s)
  • Safety parameters, Performance Level,
    c
  • Safety parameters, Performance Level, Fault exclusion
    d
  • Temperature, storage and transport temperature,[generated product variant]
    -25 ... +85 °C
  • Temperature, storage and transport temperature, maximum
    85 °C
  • Temperature, storage and transport temperature, minimum
    -25 °C
  • Type of Execution, IP Protection class, General  [generated product range]
    IP67
  • Type of execution, mounting, Screw head
    Flat head screw
  • Standard, standards [generated product range]
    EN ISO 14119, EN IEC 60947-5-1
  • Tolerance, Actuating play in direction of actuation
    5.5 mm
  • Note, Emergency release
    For cases of danger
    Mounting only outside the guarded area
  • Selection (Yes/No), Emergency release
    Yes
  • This product is unavailable

    This product is currently unavaliable, this could be due to a limited stock shortage, or because of discontinuation or replacement. For more information please contact us at b2b@tipteh.si.

  • Manufacturer Schmersal