EX-CSS 8-180-2P+D-M-L-3G/D EX machine safety sensor

EX-CSS 8-180-2P+D-M-L-3G/D
Pre-wired cable 7-pole
Comfortable diagnostics through sensor LED and electronic signalling output

Thermoplastic enclosure
Electronic contact-free, coded system
Ø M18
Misaligned actuation possible
High repeat accuracy of the switching points
Max. length of the sensor chain 200 m
Early warning when operating near the limit of the sensor's hysteris range
Self-monitoring series-wiring of 16 sensors
2 short-circuit proof PNP safety outputs
Explosion protection for ATEX Zones 2 and 22
  • SKU
    4030661347158
  • Manufacturer code
    101189302
  • CAD, traceparts, product ID
    33-22052019-077908
  • Explosion protection parameters, designation

    D II 3G Ex nA IIB T6 Gc X


    D II 3G Ex nA IIC T6 Gc X
    D II 3D Ex tc IIIC T70°C Dc X
  • Housing material
    Glass-fibre, reinforced thermoplastic
  • PIM maintenance status
    Discharge "Online catalog"
  • SAP, basic quantity unit
    Piece
  • SAP, EAN (European Article Number)
    4030661347158
  • SAP, product group
    Initial
  • SAP, gross weight
    135.000 g
  • SAP, net weight
    135.000 g
  • Included in delivery, number and type, mounting material
    2x nuts M18 x 1
  • Web Type
    Product range
  • Type of Execution, Housing construction form
    Cylinder, thread
  • Type of Execution, Terminals, mechanical
    not flush
  • Type of Execution, IP Protection class, General
    IP67
    IP65
  • Diameter, Wire cross-section, AWG
    23 AWG
  • Diameter, Wire cross-section,
    0.25 mm<sup>2</sup>
  • Length, Cable
    2 m
  • Length, Sensor
    92 mm
  • Diameter, Sensors, Metric ISO-Thread
    M18
  • Area, ensured switch distance OFF Sar
    10 mm
  • Area, ensured switch distance ON Sao
    7 mm
  • Energy, Impact energy, maximum
    2 J
  • Explosion protection, Manufacturer's declaration
    ATEX Zone 2 and 22
  • Explosion protection parameters, category
    3D
    3G
  • Explosion protection, regulations
    EN IEC 60079-0
    EN 60079-31
    EN IEC 60079-15
  • Explosion protection parameters, zones
    22
    2
  • Note, General
    Series-wiring of sensors: 16 safety sensors can be switched
    The voltage drop over a long sensor chain should be taken in
  • Number, cable wires, indication with cable cross-section, electrical
    7
  • Recommendation, actuator
    CST 180-1
    CST 180-2
  • Type of electrical connection
    Cable
  • Review, Resistance to vibrations to EN 60068-2-6
    10 … 55 Hz, amplitude 1 mm
  • Review, restistance to shock
    30 g / 11 ms
  • Safety parameters, Mission time
    20 Year(s)
  • Safety parameter
    EN ISO 13849-1
    EN IEC 61508
  • Included in delivery, number and type, general
    Actuator must be ordered separately.
  • Temperature, Ambient temperature[generated product variant]
    -25 ... +40 °C
  • Temperature, ambient temperature, maximum
    40 °C
  • Temperature, ambient temperature, minimum
    -25 °C
  • Temperature, storage and transport temperature,[generated product variant]
    -25 ... +85 °C
  • Temperature, storage and transport temperature, maximum
    85 °C
  • Temperature, storage and transport temperature, minimum
    -25 °C
  • Selection (Yes/No), Short-circuit recognition
    Yes
  • Selection (Yes/No), Short circuit detection
    Yes
  • Type of Execution, Switching output, Digital output, electric
    p-type
  • Diameter, width across flats, abbreviation
    24 BK
  • Material, nut
    Glass-fibre, reinforced thermoplastic
  • Tightening torque, torque, nuts, maximum
    3 Nm
  • Selection (Yes/No), Integral System Diagnostics, status
    Yes
  • Current, Residual current, Fail-safe output, maximum
    0.5 mA
  • Current, Rated operating current
    1000 mA
    500 mA
  • Current, Utilisation category DC-12, Diagnostic output
    0.05 A
  • Current, Utilisation category DC-12, Fail-safe digital output
    0.5 A
  • Current, Utilisation category DC-13, Diagnostic output
    0.05 A
  • Current, Utilisation category DC-13, Fail-safe digital output
    0.5 A
  • Type of Execution, for degree of pollution VDE 0100
    3
  • Type of Execution, Overvoltage category VDE 0100
    3
  • Type of Execution, Overvoltage category IEC/EN 60664-1
    II
  • Type of Execution, Protection class (Operating resource)
    2
  • Type of execution, sensor, topology
    Sensor for series wiring
  • Type of execution, switching output, fail-safe output, electric
    p-type
  • Distance, Hysteresis, Mechanical, maximum
    0.7 mm
  • Distance, Repeat accuracy R R
    0.2 mm
  • Range, switch distance S, typical
    8 mm
  • Electrical data, Connector 1, Pin assignment, PIN 1
    A1 Ue Brown
  • Electrical data, Connector 1, Pin assignment, PIN 2
    Y2 Safety output 2 red
  • Electrical data, Connector 1, Pin assignment, PIN 3
    A2 GND Blue
  • Electrical data, Connector 1, Pin assignment, PIN 4
    Y1 Safety output 1 Black
  • Electrical data, Connector 1, Pin assignment, PIN 5
    X1 Safety input 1 violet
  • Electrical data, Connector 1, Pin assignment, PIN 6
    X2 Safety input 2 White
  • Electrical data, Connector 1, Pin assignment, PIN 7
    Signalling output Grey
  • Electrical data, Fuse rating, General
    short-circuit proof, p-type
  • Elektrische Daten, Absicherung des Sicherheitsausganges, Allgemein
    short-circuit proof, p-type
  • Electrical data, Utilisation category DC-12, Diagnostic output [generated product variant]
    24 VDC / 0.05 A
  • Electrical data, Terminal connector, Output
    7-pole
  • Material, active area
    Glass-fibre, reinforced thermoplastic
  • Note, Characteristic curve
    S: switching distance
    V: Axial misalignment
    Son: Switch-on distance
    Soff: Switch-off distance
    Sh: Hysteresis area
    Sao: Assured switching distance ON
    Sar: Ensured switch distance "OFF"
  • Note, LED switching conditions display
    Multi-coloured LED: Green, Red, Yellow
  • Number, Semi-conductor outputs with signaling function
    1
  • Number, fail-safe digital outputs
    2
  • Number, Series-wiring of sensors
    16
  • PNV, standard, certificates
    TÜV
  • Safety parameters, Category, EN ISO 13849
    4
  • Safety parameters, Performance Level,
    e
  • Safety values, PFD value
    0.0000000025 /h
  • Safety parameters, Safety Integrity Level (SIL)
    3
  • Time, Duration of risk, maximum
    30 ms
  • Time, Reaction, maximum
    30 ms
  • Time, switching frequency, approx.
    3 Hz
  • Tolerance, operating voltage, DC, maximum
    10 %
  • Tolerance, operating voltage, DC, minimum
    -15 %
  • Voltage, voltage drop Ud, maximum
    0.5 V
  • Voltage, Operating voltage, maximum
    26.4 VDC
  • Voltage, Operating voltage, minimum
    20.4 VDC
  • Voltage, Rated impulse withstand voltage
    0.8 kV
  • Voltage, rated insulation voltage
    32 VDC
  • Voltage, rated operating voltage
    24 VDC
  • Voltage, rated operating voltage
    24 VDC
  • Voltage, type
    DC
  • Voltage, Utilisation category DC-12, Diagnostic output
    24 VDC
  • Voltage, Utilisation category DC-12, Fail-safe digital output
    24 VDC
  • Voltage, Utilisation category DC-13, Diagnostic output
    24 VDC
  • Voltage, Utilisation category DC-13, Fail-safe digital output
    24 VDC
  • Selection (Yes/No), Safety functions
    Yes